Key Service
- Ultrasonic Pulse Velocity (UPV) – Measures the velocity of ultrasonic waves through concrete to assess material uniformity, internal defects, and strength estimation.
- Ultrasonic Pulse-Echo (UPE) – Uses ultrasonic wave reflection to detect delamination, voids, and internal cracks in concrete and structural elements.
- Ground Penetrating Radar (GPR) – Employs electromagnetic waves to map subsurface features, including rebar positioning, voids, and hidden defects in concrete and soil.
- Digital Rebound (Schmidt) Hammer (RH) – Evaluates surface hardness and relative compressive strength of concrete by measuring the elastic rebound of a spring-loaded mass.
- Concrete Cover Scanning – Determines the depth of concrete cover over reinforcement to ensure compliance with durability and fire resistance standards.
- Steel Reinforcing Size and Arrangement – Identifies rebar diameter, spacing, and orientation within concrete structures to verify design specifications and structural integrity.
- Concrete Resistivity – Assesses the probability of corrosion in reinforced concrete by measuring electrical resistivity of the concrete as it plays electrolyte role in reinforcing steel corrosion process. (Evaluates the risk of steel reinforcement corrosion by measuring the electrical resistivity of the concrete, a key factor in its performance as an electrolyte.)
- Steel Reinforcement Corrosion Monitoring (GPT Method) – Assesses active corrosion in embedded steel reinforcement using Galvanostatic Pulse Transient Testing, allowing for early detection and preventative maintenance planning.
Completed Projects
Blowering Dam Dividing Wall Safety Review and Temporary Bulk Gate Design
Blowering Dam Access Road, Wereboldera, NSW
Comprehensive Level 3 Structural Inspection, NDT, Modelling, Load Rating, and Repair Strategy for 56 Bridges and Major Culverts
Queensland Outback – Boulia, Winton, Longreach, Jundah, Blackall, QLD
Detailed Structural and Durability Assessment, Repair Strategy, Repair Tender Preparation for Griffith Water Treatment Plant
Griffith, NSW
Durability and Design Life Compliance Review and Advisory Report of Reinforced Concrete Slabs
Aquinas College Basketball Courts, 46 Great Ryrie Street, Ringwood, VIC
Inspection, Condition Assessment, Modelling, and Design Control of an 11 ML Concrete Water Tank
Kerr St, Wangaratta, VIC
Inspection, Non-Destructive Testing (NDT), and Structural Assessment of Beechworth Swimming Pool
Beechworth Swimming Pool, Beechworth VIC
Level 2 Visual Inspection, Condition Assessment, Load Rating, and Drawing Preparation for 182 Bridges and Major Culverts
Wodonga, VIC
Level 3 Inspection, NDT, Structural Assessment, and Repair Design with Cost Estimation of 6-Span Composite Steel Girder Road Bridge
Wodonga, VIC
Level 3 Inspection, NDT, Structural Assessment, and Repair Design with Cost Estimation of 6-Span Composite Steel Girder Road Bridge
Athole Road Bridge, NSW
Level 3 Inspection, Non-Destructive Testing (NDT), Structural and Durability Assessment of Three Sewage Pump Stations, Including Repair Design
Griffith, NSW
Structural and Material Quality Assessment of Dam Spillway Concrete Slab Using Tomographic Survey
Kangaroo Creek Dam, SA