ASSESSMENT

Structural, Durability, Safety

At TechnoCrete, our Assessment and Diagnosis service provides a comprehensive evaluation of existing buildings, structures, and infrastructure assets to determine their current condition, structural adequacy, and long-term performance. This service is essential for ensuring safety, planning maintenance, guiding rehabilitation strategies, and extending the service life of critical assets.

We combine field investigations, advanced testing methods, and engineering analysis to develop a clear and accurate understanding of structural behaviour and deterioration mechanisms. Our approach is both diagnostic and predictive, enabling informed decision-making for asset owners, managers, and stakeholders.

Projects Send Us An Enquiry

Assessment Approach

TechnoCrete’s Assessment and Diagnosis service is grounded in engineering precision.

By combining field investigation and Non-Destructive Testing (NDT) with structural FE modelling, load-bearing capacity calculations, and service life prediction, TechnoCrete delivers clear and actionable insights into asset behaviour and long-term performance.

We aim not only to identify problems but to provide the engineering intelligence required to manage assets and infrastructures safely, efficiently, and sustainably throughout their lifecycle.

Visual Inspection and Condition Assessment
Icon

The assessment process begins with detailed visual inspections carried out by experienced structural engineers. This includes identifying signs of distress such as cracking, corrosion, deflection, spalling, leakage, and material degradation.
These inspections form the foundation of our condition assessment, allowing us to map damage, classify severity, and identify potential causes of deterioration.

Non-Destructive Testing (NDT)
Icon

TechnoCrete employs a wide range of non-destructive testing techniques to evaluate the internal condition of structural elements without causing damage. These methods provide critical insights into material integrity and hidden defects.
Typical NDT techniques include but not limited to:

  • Rebound hammer testing (RH)
  • Ultrasonic pulse velocity (UPV)
  • Ultrasonic-Pulse Echo (UPE)
  • Ground-penetrating radar (GPR)
  • Corrosion Monitoring and Measurement of Corrosion Parameters such as Corrosion Potential, Resistivity, and Corrosion Current Density
  • Cover meter surveys
  • Infrared thermography using Drone

These tools allow us to assess reinforcement condition, concrete quality, voids, and other hidden structural issues with high accuracy.

Asset Evaluation & Management
Icon

We implement intelligent monitoring systems that provide continuous tracking of structural behaviour, allowing early detection of weaknesses and proactive maintenance planning.

Load-Bearing Capacity Evaluation

A key component of our service is the determination of the load-bearing capacity of existing structures. We assess whether structures can safely continue to carry current loads or accommodate proposed changes in use, loading, or configuration.
This includes evaluating:

  • Ultimate and serviceability limit states
  • Strength reduction due to deterioration
  • Structural redundancy and load distribution
  • Safety margins under current conditions
Service Life Modelling and Prediction

TechnoCrete provides advanced service life modelling and prediction to estimate the remaining useful life of structures based on observed conditions, environmental exposure, and material deterioration mechanisms.
This predictive approach enables asset owners to:

  • Plan maintenance and rehabilitation strategies
  • Prioritise interventions based on risk
  • Optimise lifecycle costs
  • Extend service life safely and efficiently

Completed Projects

Blowering Dam Dividing Wall Safety Review and Temporary Bulk Gate Design
Blowering Dam Access Road, Wereboldera, NSW
Blowering Dam Dividing Wall Safety Review and Temporary Bulk Gate Design
Comprehensive Level 3 Structural Inspection, NDT, Modelling, Load Rating, and Repair Strategy for 56 Bridges and Major Culverts
Queensland Outback – Boulia, Winton, Longreach, Jundah, Blackall, QLD
Comprehensive Level 3 Structural Inspection, NDT, Modelling, Load Rating, and Repair Strategy for 56 Bridges and Major Culverts
Detailed Structural and Durability Assessment, Repair Strategy, Repair Tender Preparation for Griffith Water Treatment Plant
Griffith, NSW
Detailed Structural and Durability Assessment, Repair Strategy, Repair Tender Preparation for Griffith Water Treatment Plant
Durability and Design Life Compliance Review and Advisory Report of Reinforced Concrete Slabs
Aquinas College Basketball Courts, 46 Great Ryrie Street, Ringwood, VIC
Durability and Design Life Compliance Review and Advisory Report of Reinforced Concrete Slabs
Inspection, Condition Assessment, Modelling, and Design Control of an 11 ML Concrete Water Tank
Kerr St, Wangaratta, VIC
Inspection, Condition Assessment, Modelling, and Design Control of an 11 ML Concrete Water Tank
Inspection, Non-Destructive Testing (NDT), and Structural Assessment of Beechworth Swimming Pool
Beechworth Swimming Pool, Beechworth VIC
Inspection, Non-Destructive Testing (NDT), and Structural Assessment of Beechworth Swimming Pool
Level 2 Visual Inspection, Condition Assessment, Load Rating, and Drawing Preparation for 182 Bridges and Major Culverts
Wodonga, VIC
Level 2 Visual Inspection, Condition Assessment, Load Rating, and Drawing Preparation for 182 Bridges and Major Culverts
Level 3 Inspection, NDT, Structural Assessment, and Repair Design with Cost Estimation of 6-Span Composite Steel Girder Road Bridge
Wodonga, VIC
Level 3 Inspection, NDT, Structural Assessment, and Repair Design with Cost Estimation of 6-Span Composite Steel Girder Road Bridge
Level 3 Inspection, NDT, Structural Assessment, and Repair Design with Cost Estimation of 6-Span Composite Steel Girder Road Bridge
Athole Road Bridge, NSW
Level 3 Inspection, NDT, Structural Assessment, and Repair Design with Cost Estimation of 6-Span Composite Steel Girder Road Bridge
Level 3 Inspection, Non-Destructive Testing (NDT), Structural and Durability Assessment of Three Sewage Pump Stations, Including Repair Design
Griffith, NSW
Level 3 Inspection, Non-Destructive Testing (NDT), Structural and Durability Assessment of Three Sewage Pump Stations, Including Repair Design
Level 3 Structural Inspection and Condition Assessment of 12 Water Reservoirs
Albury NSW
Level 3 Structural Inspection and Condition Assessment of 12 Water Reservoirs
Structural & Durability Assessment of Turbine Tail Bay (Power Station)
Clover Power Station, VIC
Structural & Durability Assessment of Turbine Tail Bay (Power Station)
Structural Analysis – Lavington Shopping Centre Regeneration Project
351 Griffith Rd, Lavington NSW
Structural Analysis – Lavington Shopping Centre Regeneration Project
Structural and Material Quality Assessment of Dam Spillway Concrete Slab Using Tomographic Survey
Kangaroo Creek Dam, SA
Structural and Material Quality Assessment of Dam Spillway Concrete Slab Using Tomographic Survey
Structural Design and Detailed Deawings – Flyfaire Wines Underground Cellar
Woomargama, NSW
Structural Design and Detailed Deawings – Flyfaire Wines Underground Cellar
Structural Design and Detailed Drawings – Retaining Wall
Michelle Ave, Lavington, NSW
Structural Design and Detailed Drawings – Retaining Wall
Structural Design and Stability Assessment of Retaining Wall, Including Drainage System Design
Samantha Riley Dr, Kellyville NSW
Structural Design and Stability Assessment of Retaining Wall, Including Drainage System Design
Structural Strengthening Design & IFC Drawings of a Concrete Bridge
Funnel Creek Road, Whitsunday Region, QLD
Structural Strengthening Design & IFC Drawings of a Concrete Bridge